
use a weighted decision matrix to compare three station designs and make an evidence-based claim about which one to build.
Phase 4: Build
Do Now. Diego says, “Let’s use the school microscope. It’s the most scientific.” What is missing from his reason?
What should a team's choice of design be based on?
A decision matrix is a fair scoring table. Each row is a design. Each column is a criterion or constraint. You score every design from 1 (poor) to 5 (excellent) on every column. Some columns matter more, so they get a weight. Multiply each score by its weight, then add across.
Setting weights together. The clinic told us that clear cells matter most, because a blurry picture teaches nothing. So clarity (magnification of 100× or more) gets a weight of 3. Cost and sharing (8 viewers at 2 m, plus sending files) each get 2. Setup time gets 1. Your class may agree on different weights; just explain why.
Worked example 1: scoring the microscope with adapter (sample scores). Clarity 5 × 3 = 15. Cost 3 × 2 = 6. Sharing 5 × 2 = 10. Setup 3 × 1 = 3. Total = 15 + 6 + 10 + 3 = 34.
Worked example 2: scoring the other two (sample scores). Clip-on lens: clarity 3 (9), cost 5 (10), sharing 4 (8), setup 5 (5), total 32. Water-drop lens: clarity 1 (3), cost 5 (10), sharing 3 (6), setup 2 (2), total 21.
| Design (sample) | Clarity ×3 | Cost ×2 | Sharing ×2 | Setup ×1 | Total |
|---|---|---|---|---|---|
| Clip-on lens | 9 | 10 | 8 | 5 | 32 |
| Water-drop lens | 3 | 10 | 6 | 2 | 21 |
| Microscope + adapter | 15 | 6 | 10 | 3 | 34 |
Reading the result. The microscope with adapter wins in this sample, but only by 2 points, and its cost and setup scores are its weaknesses. A strong claim names those weaknesses and a plan, such as borrowing a microscope and writing picture setup steps. Notice too that a design that fails a must-have, such as reaching less than 100×, may be out even with a good total.
| Our design | Clarity ×3 | Cost ×2 | Sharing ×2 | Setup ×1 | Total |
|---|---|---|---|---|---|
| Clip-on lens | |||||
| Water-drop lens | |||||
| Microscope + adapter |
Score your matrix as a team, then check your thinking.
Write your design claim.
Using your team's matrix, write a claim about which design to build. Give the total, one strength, one weakness, and how you will fix the weakness.
Which design would you choose if the clinic already owned a school microscope? Explain how that changes the cost score.
You chose with evidence. Next class we learn how health workers already share microscope pictures over long distances.
Exit ticket: name the design your team chose, its total, and the one weakness you must fix in the build.
How confident are you that you can I can use a decision matrix to find the strengths and weaknesses of each solution.
Materials: blank matrix sheets, calculators, the criteria poster, sample designs from 3.15.
Setup: agree on class weights in a 5-minute discussion before teams score. Real lens prices vary; use your own class price list and remind students that the scores here are sample data.
Listen for: teams adding raw scores without weights; ignoring a must-have constraint; claims with no number in them.
Support / stretch: pre-fill the weight row and one design. Stretch: run a “sensitivity check” by changing one weight and seeing if the winner changes.