THE VR SCHOOL
  • Schools & Districts
    • License the academy
    • Free program for your students
    • Request a demo
  • Catalog
    • AI & Data
    • Cybersecurity & Web
    • Programming
    • Health Science
    • All Guilds
    • All courses
  • Families
  • Accreditation
  • Log In
  • Request a demo
  • Home
  • Courses

RLP Physics B — Energy, Thermal Physics, Electromagnetism and Waves

Curriculum

  • 5 Sections
  • 23 Lessons
  • 10 Weeks
Expand all sectionsCollapse all sections
  • Unit 1: Energy, Work and Power
    5
    • 1.1
      Pumped Storage: Work, Kinetic and Potential Energy
      50 mins
    • 1.2
      Ramp Lab: Measuring Energy Transfer and Efficiency
      100 mins
    • 1.3
      Where Did the Energy Go? Springs, Rubber Bands and Thermal Energy
      100 mins
    • 1.4
      Power and a Pumped-Storage Day: A Computational Energy Model
      100 mins
    • 1.5
      Performance Task — Design, Build and Refine an Energy Converter
      200 mins
  • Unit 2: Thermal Energy and the Second Law
    5
    • 2.1
      Why a Dark Roof Gets Hotter: Temperature, Thermal Energy and Heat
      50 mins
    • 2.2
      Specific Heat by the Method of Mixtures
      100 mins
    • 2.3
      Why Heat Flows Downhill: The Second Law and Engine Limits
      50 mins
    • 2.4
      Particles, Pressure, Heat Pumps and Insulating Materials
      100 mins
    • 2.5
      Performance Task — Keep It Cold in a Missouri Summer
      200 mins
  • Unit 3: Electricity and Magnetism
    5
    • 3.1
      Missouri Winter Sparks: Charge and Coulomb’s Law
      100 mins
    • 3.2
      Circuit Lab: Ohm’s Law, Series and Parallel with a Multimeter
      100 mins
    • 3.3
      Do Currents Make Magnetic Fields? Electromagnet Evidence and Argument
      100 mins
    • 3.4
      Fields, Induction and the Wind Turbines of Atchison County
      100 mins
    • 3.5
      Performance Task — Wind to Wire: Modeling a Transmission Link
      150 mins
  • Unit 4: Waves, Light and Information
    5
    • 4.1
      Seconds of Warning: Wave Speed and the New Madrid Seismic Zone
      50 mins
    • 4.2
      Investigation Lab: Standing Waves on a Stretched String
      100 mins
    • 4.3
      Argument Lab: Is Digital Always Better?
      50 mins
    • 4.4
      Light as Wave and Particle: Refraction, Photons and the Spectrum
      100 mins
    • 4.5
      Performance Task — Technical Brief: Waves That Carry Information and Energy
      150 mins
  • Unit 5: Missouri Physics Supplement
    3
    • 5.1
      Stars, Elements and the Big Bang
      50 mins
    • 5.2
      Earth’s Crust and Earth’s Story
      50 mins
    • 5.3
      Earth’s Energy and Feedbacks
      50 mins

Pumped Storage: Work, Kinetic and Potential Energy

Unit 1  ·  Phenomenon Launch & Questioning  ·  Lesson 1 of 23

Pumped Storage: Work, Kinetic and Potential Energy

9-12.PS3.A.1RLP-PHYB
Cutaway pumped-storage mountain with upper and lower reservoirs, water rising through pumps and descending through a turbine-generator.
By the end of this lesson I can…

calculate the work done by a force at an angle, the kinetic and gravitational potential energy of an object, and show with an energy bar chart how energy moves through a pumped-storage system.

Instruction

The phenomenon. On top of Proffit Mountain in Reynolds County, about 120 miles southwest of St. Louis, Ameren Missouri keeps a lake. It is the upper reservoir of the Taum Sauk pumped-storage plant, and Ameren says it holds “1.5 billion gallons of water.” A second, lower reservoir sits at the foot of the mountain. Overnight, when demand for electricity is low, electric pumps push water up to the mountaintop. When demand peaks, the water runs back down through the same machines working as turbines and generators, which can deliver up to 440 MW. No fuel is burned. Ameren’s own resource plan gives the plant a “pump back efficiency of 0.714.” The question for this unit: where is the energy while the water sits on the mountain, and why do we get back less than we put in?

Work. A force transfers energy into or out of a system by doing work: W = Fd cos θ, where F is the force, d the displacement and θ the angle between them. Work is measured in joules (1 J = 1 N·m). Only the part of the force along the motion counts.

Worked example. You pull a rolling suitcase 20 m through an airport with a 60 N force on the handle at 35° above the floor. W = (60 N)(20 m) cos 35° = 983 J. Had you pulled horizontally, all 1,200 J would count; pulling at an angle wastes part of your force lifting on the handle, which does no work along the floor.

Three cases to remember. If the force points along the motion (θ = 0°), W = Fd. If it is perpendicular (θ = 90°), W = 0: carrying a box across a room at steady height, your upward push does no work on it. If it opposes the motion (θ = 180°), the work is negative and energy leaves the object: 12 N of friction on a box sliding 3 m does W = −36 J.

Kinetic energy. A moving object has KE = ½mv2. The work-energy theorem says the net work on an object equals its change in kinetic energy. A 1,200 kg car going from rest to 15 m/s gains ½(1,200)(15)2 = 135,000 J. If that happens over 100 m, the average net force was 135,000 J ÷ 100 m = 1,350 N. Speed is squared, so doubling speed quadruples kinetic energy.

Gravitational potential energy. Lifting a mass m a height h at steady speed takes a force mg through distance h, so the work done is mgh, and the Earth-object system stores ΔPE = mgh. Pumped storage runs on this. Taum Sauk’s maximum operating head (height difference) is 860 ft, or 262 m. One cubic meter of water has a mass of 1,000 kg, so lifting it stores (1,000)(9.8)(262) = 2.57 × 106 J = 0.713 kWh. The full upper reservoir, 1.5 billion gallons or 5.68 × 106 m3, stores at most about 1.46 × 1013 J, or 4,050 MWh: enough to run the plant at 440 MW for about 9 hours. (“At most” because 262 m is the maximum head; water near the bottom of the upper reservoir falls less far.) If one kilogram fell the full 262 m with nothing in the way, it would reach √(2gh) ≈ 72 m/s. In the plant, the turbine takes that energy instead, and the water leaves slowly.

Energy belongs to a system. Potential energy is not stored “in the water”. It belongs to the water-Earth system, because it depends on their separation. Always name your system first. If the system is water + Earth, the pump’s push is external work that adds energy. If the system is water + Earth + pump + grid, the energy has only changed form. Energy is conserved: it is transferred or transformed, never created or destroyed.

Energy bar charts. A bar chart shows the energy accounting. The chart below splits Taum Sauk’s published round trip of 71.4% into illustrative pump and turbine efficiencies of 85% and 84% (0.85 × 0.84 = 0.714). Of 100 units of electrical energy used for pumping overnight, 85 end up as gravitational potential energy and 15 become thermal energy in the motors and water. At the peak, the 85 units return as 71.4 units of electricity. The U.S. Energy Information Administration reports that the nation’s pumped-storage plants averaged a 79% round trip in 2019, so Taum Sauk, built in 1963, sits near the low end of the common 70-80% range.

Overnight: pumping100elec in85GPE15thermalPeak: generating85GPE71.4elec out13.6thermal

Common misconceptions. (1) “Holding something heavy is work.” Your muscles use energy, but no work is done on the object if it does not move. (2) “Energy is used up.” It is transformed, mostly into thermal energy that spreads out and is hard to use again. (3) “Pumped storage makes energy.” It only stores energy that was generated elsewhere, and returns less of it.

📖 Read for this lesson

The reading opens over the lesson; close it to come back to exactly where you were. The checks below draw on it.

  • Taum Sauk by the Numbers: Ameren’s Figures, the Plant’s Measured Round Trip and the 2005 BreachAmeren Missouri, Taum Sauk Pumped Storage Energy Center (presentation filed with the Missouri Public Service Commission, EFIS document 268949); Ameren Missouri 2011 Integrated Resource Plan, chapter 5 (EFIS document 55215); Ameren Missouri, Taum Sauk Energy Center web page; EIA Form EIA-923 plant data for Taum Sauk (plant 2108), 2021-2025, via the EIA API v2; EIA Today in Energy, July 8, 2013 and Feb. 12, 2021; Association of State Dam Safety Officials, Dam Failure Case Study: Taum Sauk Dam (Missouri, 2005); retrieved November 5, 2026 · about 6 min

    Ameren Missouri’s published figures for Taum Sauk (head, capacity, reservoir volume and 0.714 pump-back efficiency), five years of the plant’s measured gross and net output from EIA Form EIA-923 and the national round trip, so the lesson’s work and potential-energy accounting can be run a second time on the real Missouri plant, along with the 2005 breach as a case of the same stored energy released without control.

Vocabulary in context

  • work — Energy transferred by a force acting through a displacement: W = Fd cos θ, in joules.
  • kinetic energy — Energy of motion, ½mv2.
  • gravitational potential energy — Energy of an object-Earth system due to their separation; a change of height h gives ΔPE = mgh.
  • system — The part of the world you choose to track; energy crosses its boundary only by work, heating or radiation.
  • pumped storage — A hydroelectric plant that pumps water to a higher reservoir when electricity is plentiful and generates by releasing it later.

Formative check

Work through these before moving on. They are not graded — they tell you whether the standard below has landed yet.

Make a prediction

A plant uses 100 MWh of electricity to pump water uphill at midday. How much electricity will it deliver when that water flows back down in the evening?

Less. Energy is conserved, but at each step some becomes thermal energy in the pumps, turbines, wires and water. Ameren gives Taum Sauk a pump back efficiency of 0.714, so about 71 MWh comes back.
+50 XP

A 60 N pull at 35° above horizontal moves a suitcase 20 m along level floor. How much work does the pull do?

W = Fd cos θ = (60)(20)(cos 35°) = 983 J. Only the component along the floor does work.
Fill in the blank

Lifting 1 m3 of water (1,000 kg) through Taum Sauk’s 262 m head stores J, which is about kWh.

Myth or Fact?

When you carry a box across a room at a constant height and speed, the upward force you exert on the box does positive work on it.

The upward force is perpendicular to the horizontal displacement (θ = 90°, cos 90° = 0), so it does no work on the box. The box’s kinetic and potential energy do not change.
Quick self-check

How confident are you that you can calculate work, kinetic energy and gravitational potential energy, and track energy through a pumped-storage system with a bar chart?

Not yetVery confident

Practice

Work these on paper or in your notebook, then open Check your answer. Aim for all of Fluency and Application; try at least one Challenge.

Printable version: this unit’s practice workbook (PDF)

Fluency

Build speed and accuracy with the core skill.

  1. Find the kinetic energy of a 0.5 kg object moving at 5 m/s.
    Check your answer
    Answer: 6.2 J
    KE = ½mv2.
  2. Find the kinetic energy of a 1000 kg object moving at 12 m/s.
    Check your answer
    Answer: 72,000 J
    KE = ½mv2.
  3. Find the gravitational potential energy gained when a 10 kg object is lifted 1.5 m (g = 9.8 m/s2).
    Check your answer
    Answer: 147.0 J
    PE = mgh.
  4. Find the gravitational potential energy gained when a 0.5 kg object is lifted 40 m (g = 9.8 m/s2).
    Check your answer
    Answer: 196.0 J
    PE = mgh.
  5. You push a lawnmower 12 m with 250 N along the handle, which points 20° below horizontal. How much work do you do on it?
    Check your answer
    Answer: 2,819 J
    W = Fd cos θ = 250 × 12 × cos 20°.
  6. How much gravitational potential energy does lifting 1,000 kg of water through 300 m store? Express it in joules and kilowatt-hours.
    Check your answer
    Answer: 2,940,000 J = 0.817 kWh
    mgh; divide by 3.6 × 106 J/kWh.

Application

Use the skill in context. Show your reasoning.

  1. A 1,500 kg car speeds up from rest to 20 m/s over 60 m. Use the work-energy theorem to find its kinetic energy and the average net force.
    Check your answer
    Answer: 300,000 J; 5,000 N
    Wnet = ΔKE; F = ΔKE/d.
  2. A frictionless roller coaster starts from rest 40 m up. How fast is it at a point 15 m above the ground? Does the answer depend on the car’s mass?
    Check your answer
    Answer: 22.1 m/s; no
    mg(40 − 15) = ½mv2, so v = √(2g × 25); m cancels.
  3. Taum Sauk’s upper reservoir holds about 5.68 × 106 m3 of water (Ameren’s 1.5 billion gallons), and its maximum head is 262 m. At most, how much energy does a full reservoir store, in GWh?
    Check your answer
    Answer: 4.05 GWh
    E = mgh with m = 5.68 × 109 kg; divide by 3.6 × 1012 J/GWh. “At most” because 262 m is the maximum head.

Challenge

Stretch problems. Expect to think before you write.

  1. A 2.0 kg box slides down a 5.0 m long ramp inclined at 30° with 4.0 N of kinetic friction, starting from rest. Use energy to find its speed at the bottom.
    Check your answer
    Answer: 5.39 m/s
    PE lost = 2.0 × 9.8 × (5.0 sin 30°) = 49.0 J; friction work = 4.0 × 5.0 = 20 J; KE = 29.0 J; v = √(2KE/m).

Review

Keep earlier skills sharp.

  1. An object starts at 5 m/s and accelerates at 1.5 m/s2 for 5 s. How far does it travel?
    Check your answer
    Answer: 43.8 m
    d = v0t + ½at2.
  2. An object starts at 7 m/s and accelerates at 3 m/s2 for 9 s. How far does it travel?
    Check your answer
    Answer: 184.5 m
    d = v0t + ½at2.

Missouri Learning Standards — Science addressed: 9-12.PS3.A.1, SEP.5, SEP.2, CCC.5, CCC.4, RST.11-12.7, MP.2

Instructional focus: Quantitative energy accounting in a defined system

Reading

Taum Sauk by the Numbers: Ameren’s Figures, the Plant’s Measured Round Trip and the 2005 Breach

Ameren Missouri, Taum Sauk Pumped Storage Energy Center (presentation filed with the Missouri Public Service Commission, EFIS document 268949); Ameren Missouri 2011 Integrated Resource Plan, chapter 5 (EFIS document 55215); Ameren Missouri, Taum Sauk Energy Center web page; EIA Form EIA-923 plant data for Taum Sauk (plant 2108), 2021-2025, via the EIA API v2; EIA Today in Energy, July 8, 2013 and Feb. 12, 2021; Association of State Dam Safety Officials, Dam Failure Case Study: Taum Sauk Dam (Missouri, 2005); retrieved November 5, 2026 · Public domain (works of the United States government) and published facts quoted from Ameren Missouri, Missouri Public Service Commission filings and the Association of State Dam Safety Officials, with SLS computations

Why this reading. Lesson 1.1 works its pumped-storage example on a real Missouri plant: Ameren Missouri’s Taum Sauk, on Proffit Mountain in Reynolds County. Every figure the lesson uses is here with its source: the plant’s size, drop and round trip from Ameren’s own documents (two of them filed with the Missouri Public Service Commission), five years of the plant’s measured output from the U.S. Energy Information Administration, the national round trip for comparison, and the night in 2005 when the stored energy left the mountain without passing through a turbine. Every calculation from those figures is shown, so you can run the lesson’s energy accounting a second time on the real plant.

Table 1. The Taum Sauk Energy Center, as Ameren describes it

ItemAs publishedSource
LocationReynolds County, Missouri; “approximately 120 miles southwest of St. Louis in the scenic Ozark highlands”Ameren PSC presentation; 2011 IRP
Production capacity440 MW, from 2 pump turbinesAmeren PSC presentation
Maximum operating head (the drop)860 ftAmeren PSC presentation
Began operation1963; upper reservoir rebuilt and back in service in 2010Ameren PSC presentation; 2011 IRP
Reservoir areasUpper 51 acres; lower 370 acresAmeren PSC presentation
Water stored“Like a giant battery, Taum Sauk Energy Center stores the natural power of 1.5 billion gallons of water”Ameren, Taum Sauk Energy Center page
How it runs“used primarily on a peaking basis and is put into operation when the demand for electricity is greatest”; “overnight, when the demand for electricity is low, the water … is pumped back into the upper reservoir”Ameren 2011 IRP
Round trip“The Taum Sauk facility has a pump back efficiency of 0.714.”Ameren 2011 IRP

Table 2. The lesson’s calculations, run on Taum Sauk

QuantityComputationResult
The drop in meters860 ft × 0.3048 m/ft262.1 m ≈ 262 m
Energy stored per cubic meter lifted the full dropmgh = 1,000 kg × 9.8 m/s2 × 262 m2,567,600 J ≈ 2.57 MJ = 0.713 kWh
Volume of the upper reservoir1.5 billion gal × 0.003785 m3/gal5.68 million m3
Energy stored in a full upper reservoir, at most5.68 × 106 m3 × 2.5676 × 106 J/m31.46 × 1013 J ≈ 4,050 MWh
Hours at 440 MW on that energy4,050 MWh ÷ 440 MWabout 9.2 hours
Speed after a free fall of 262 m√(2 × 9.8 × 262)71.7 m/s ≈ 72 m/s
Water flow needed for 440 MW, if every joule became electricity440 × 106 W ÷ (1,000 × 9.8 × 262)171 m3/s
The same, with the lesson’s illustrative 84% turbine-generator efficiency171.4 ÷ 0.84about 204 m3/s

Why “at most.” 860 ft is the maximum operating head: the drop from a full upper reservoir. Water near the bottom of the upper reservoir falls less far, and turbines and generators are not perfect, so the electricity from one full reservoir is less than 4,050 MWh. One cubic meter is worth only 0.713 kWh, about 43 minutes of a 1,000 W microwave; that is why the plant needs millions of cubic meters to matter to the grid.

Table 3. What comes back: Taum Sauk’s measured record (EIA Form EIA-923)

The EIA publishes each power plant’s generation. For a pumped-storage plant it reports gross generation (electricity the generators produced) and net generation, which subtracts the electricity the plant used, almost all of it for pumping. Net generation is negative because pumping takes more than generating gives back. So gross − net is the electricity that went in, and gross ÷ (gross − net) is the fraction returned. (The plant’s own station use is counted in “in”, so this is a slight underestimate of the pumping round trip.) Retrieved from the EIA API on November 5, 2026, plant code 2108.

YearGross generation (MWh)Net generation (MWh)Electricity in (MWh)Fraction returned
2021238,980−86,065238,980 + 86,065 = 325,04573.5%
2022384,561−147,865384,561 + 147,865 = 532,42672.2%
2023340,403−129,965340,403 + 129,965 = 470,36872.4%
2024342,877−132,980342,877 + 132,980 = 475,85772.1%
2025415,892−159,810415,892 + 159,810 = 575,70272.2%

Every year lands between 72% and 74%, right beside Ameren’s published 0.714. The lesson’s illustrative split, 85% for pumping and 84% for generating, multiplies to the same 0.714.

Table 4. The national fleet, for comparison

EIA, Today in Energy, July 8, 2013: in 2011 U.S. pumped-storage plants “produced 23 billion kilowatthours (kWh) of gross generation” and “consumed 29 billion kilowatthours (kWh) of electricity … to refill their storage reservoirs, resulting in a net generation loss of 6 billion kWh,” with “40 pumped storage plants operating in the United States … totaling more than 22 gigawatts (GW) of storage capacity.” That is 23 ÷ 29 = 79% returned. EIA, Today in Energy, Feb. 12, 2021: in 2019 “pumped-storage facilities operated with an average monthly round-trip efficiency of 79%.” Taum Sauk, which began running in 1963, returns several points less than the national average.

Table 5. Stored energy out of control: December 14, 2005

The Association of State Dam Safety Officials’ case study reports that the original upper reservoir “failed by overtopping during the final minutes of one of its pumping cycles.” Its 4,300 acre-feet of water left through a breach 656 ft wide in 25 minutes, with a peak discharge of 273,000 cubic feet per second, and destroyed 281 acres of Johnson’s Shut-Ins State Park before the lower reservoir contained it. The case study notes that loss of life was averted “by chance alone.”

QuantityComputationResult
Water released4,300 acre-ft × 1,233.48 m3/acre-ft5.30 million m3
Gravitational energy released, estimated with the plant’s 262 m head5.30 × 106 m3 × 1,000 kg/m3 × 9.8 × 262about 1.36 × 1013 J
Average power of the flood1.36 × 1013 J ÷ (25 × 60 s)about 9.1 × 109 W, about 21 times the plant’s 440 MW

The systems lesson. The energy is the same mgh whether it leaves through the turbines over nine hours or down a mountainside in 25 minutes. What changes is the path and the rate, which is to say the power. The rebuilt reservoir’s level-control instruments, listed in Ameren’s presentation to the Public Service Commission (level probes, a float switch, a video camera and staff gauge, an overflow release structure and redundant power), exist to keep the energy on the slow path.

Your turn

  1. Redraw the lesson’s two energy bar charts for 100 units of electrical energy using Taum Sauk’s 2025 EIA figure of 72.2%, split equally between pumping and generating (√0.722 = 0.850 each way). Label every bar.
  2. Suppose the upper reservoir has been drawn down so that the drop is only 800 ft. Compute the energy stored per cubic meter at that drop in joules and kWh, and explain in one sentence why the plant gets less energy from its last cubic meters than from its first.
  3. Using Ameren’s 0.714, how much electricity must be used for pumping to deliver 1,000 MWh at the peak, and how much ends up as thermal energy? Name the system you used.
  4. Taum Sauk loses more than a quarter of the energy it stores. Using Table 1’s description of when it pumps and when it generates, explain in two sentences why the plant is still worth running.

Sources: Ameren Missouri, Taum Sauk Pumped Storage Energy Center (presentation filed with the Missouri Public Service Commission, EFIS 268949) (efis.psc.mo.gov); Ameren Missouri, 2011 Integrated Resource Plan, Chapter 5: Renewable and Storage Resources (EFIS 55215) (efis.psc.mo.gov); Ameren Missouri, Taum Sauk Energy Center (ameren.com); EIA Open Data API v2, electricity/facility-fuel (Form EIA-923), plant 2108 Taum Sauk, annual and monthly net and gross generation (api.eia.gov); EIA, Today in Energy: Pumped storage provides grid reliability even with net generation loss (July 8, 2013) (eia.gov); EIA, Today in Energy: Utility-scale batteries and pumped storage return about 80% of the electricity they store (Feb. 12, 2021) (eia.gov); Association of State Dam Safety Officials, Dam Failure Case Study: Taum Sauk Dam (Missouri, 2005) (damsafety.org)

Up NextComplete & Continue →

Leave a Reply Cancel reply

Ramp Lab: Measuring Energy Transfer and Efficiency
Next

© 2026 The VR School | Career content by Wiley | Powered by Sejal Learning Systems.

Join free · Accreditation · Privacy Policy · Terms of Service

Modal title

Main Content