give and use evidence-based critique to improve our interactive, explain how technetium-99m imaging works with nuclear equations and half-life, and compare radiation doses in sieverts to explain radiation safety.
Phase 4: Build
Do Now. A friend’s grandmother had a bone scan and was told she would be “slightly radioactive” for the rest of the day. Write what you think that means and one question you would ask her doctor.
Technetium-99m has a half-life of 6.0 hours. What fraction is left in a patient's body one day after a scan, not counting any that leaves in urine?
Gallery critique. Teams set up version 1 and rotate through the other stations as test visitors. Leave three sticky notes at each: green, something that works and why; yellow, a change, tied to a criterion; blue, a question a visitor might ask. Feedback is about designs and evidence, never about people. Then each team picks the two changes most likely to raise its lowest criterion score.
The medical panel: how a hospital makes its isotope. Technetium (Z = 43) has no stable isotopes, so hospitals make it fresh. Molybdenum-99, produced in research reactors mostly by the fission of uranium-235, is shipped in a shielded generator. Inside, it decays by beta-minus emission (t1/2 = 66 hours): 9942Mo → 99m43Tc + 0−1e. Mass 99 = 99 + 0; charge 42 = 43 + (−1). Each morning technologists rinse the newly made technetium-99m out of the generator, attach it to a carrier molecule that collects in bone, heart muscle or another target, and inject it.
Why technetium-99m is nearly ideal. It decays by gamma emission alone: 99m43Tc → 9943Tc + γ, with a gamma-ray energy of 140 keV. Gamma rays leave the body and reach a gamma camera, which builds an image of where the tracer collected; there is no alpha or beta particle to deposit energy in the tissue. Its 6.0-hour half-life is long enough to prepare and scan, and short enough that the activity fades within a day or two. The product, technetium-99, decays so slowly (half-life about 211,000 years) that its activity is tiny. Technetium-99m is used in tens of millions of scans a year worldwide, more than any other medical isotope.
Worked example 1: decay of a dose. Andre’s hospital fact sheet (sample values within the typical range) lists a bone-scan dose of 740 megabecquerels (MBq; 1 Bq = 1 decay per second). After 24 hours: 740 × (1/2)4 = 46 MBq from decay alone. After 48 hours (8 half-lives): 740 ÷ 256 = 2.9 MBq. In the generator, the molybdenum-99 parent has fallen to only 1/2 after 66 hours, so one generator supplies a department for about a week.
Measuring dose. The gray (Gy) is the energy absorbed per kilogram of tissue, 1 Gy = 1 J/kg. The sievert (Sv) adjusts the gray for how damaging each kind of radiation is: for gamma rays and beta particles the factor is 1, for alpha particles it is 20, because alphas deposit their energy in a very short track. Everyday doses are in millisieverts (mSv). NCRP Report No. 160 estimated that people in the United States receive on average about 3.1 mSv per year from natural background (about three-quarters from radon gas in homes, the rest from cosmic rays, rocks and soil, and the potassium-40 and carbon-14 in our own bodies), plus a similar average amount from medical imaging.
Worked example 2: putting a dose in context. Leila compared a chest X-ray of about 0.1 mSv with natural background. Background per day = 3.1 mSv ÷ 365 = 0.0085 mSv. 0.1 ÷ 0.0085 ≈ 12, so a chest X-ray equals about 12 days of natural background. A technetium-99m bone scan gives a few mSv, comparable to one to two years of background, which doctors weigh against the value of finding a fracture or a tumor early.
Time, distance, shielding. Radiation workers keep doses as low as reasonably achievable by limiting time near a source, increasing distance (gamma intensity falls with the square of distance: twice as far, one-quarter the dose) and using shielding matched to the radiation. An alpha source is harmless outside the body, because skin stops it, but dangerous if swallowed or inhaled; that is why a smoke detector’s americium is sealed in a metal chamber and the detector must never be opened.
Reading. OpenStax Chemistry 2e, sections 21.5 (uses of radioisotopes) and 21.6 (biological effects of radiation), CC BY 4.0; NCRP Report No. 160, Ionizing Radiation Exposure of the Population of the United States (2009).
Use the critique notes, the medical fact sheet and a calculator.
Build and test version 2, then draft the medical panel.
Compare version 1 and version 2 on every criterion in the measures table. Which criterion improved most, and what did you give up to get it?
Draft the medical isotope panel (150–200 words): the two nuclear equations from molybdenum-99 to technetium-99, why the half-life and the gamma ray make it useful, and one dose comparison in millisieverts with its source. Add one sentence linking it to the smoke detector's americium-241 and how each source is kept safe.
Version 2 is tested and the medical panel is drafted. Next phase, you assemble the exhibit and present it to the museum’s review panel.
Exit ticket: a visitor asks, “If radiation is dangerous, why would a doctor put it inside me?” Answer in three sentences using half-life, gamma rays and dose.
Materials: version 1 interactives, sticky notes in three colors, a printed medical fact sheet (generic hospital) with the Mo-99/Tc-99m values, calculators, timers for test visitors.
Timing: critique 15 minutes, medical mini-lesson 15 minutes, version 2 and test 20 minutes; the panel draft can finish as homework.
Answers: 400 MBq at 2:00 p.m. = 200 MBq. Career example: to deliver 740 MBq at 10 a.m., measure 740 ÷ (1/2)2/6 = 740 × 1.26 = 932 MBq at 8 a.m.
Note: dose figures for scans vary by procedure and patient; students should cite the source of any number they use. The NCRP 160 medical average (about 3.0 mSv) reflects 2006 data and has changed since; the natural background figure is the one to quote.
Listen for: “the patient becomes radioactive forever”; “all radiation is the same”; critique aimed at people instead of designs.
Support / stretch: provide critique sentence starters and a dose comparison bar chart template. Stretch: fluorine-18 for PET has a half-life of 110 minutes; explain why PET centers are usually close to the cyclotron that makes it, and write its positron-emission equation.