trace the energy conversions in a power plant, hand warmer and pumped-storage plant, calculate efficiency from a heat rate, and use a model to explain where the energy goes and how a design could waste less.
Instruction
The phenomenon. Coal supplied 58.1 percent of Missouri’s electricity in 2024, yet a coal plant converts only about a third of the energy in its fuel into electricity. Where does the rest go? Elsewhere on the grid, Ameren Missouri describes the Taum Sauk Energy Center as storing the energy of 1.5 billion gallons of water, “like a giant battery.” In 2023 Missouri’s pumped-storage plants used 49,050 MWh more electricity than they generated (EIA net generation of −49,050 MWh). Both are energy conversion devices, and both lose energy as heat.
Energy conversion and efficiency. A device converts energy from one form to another: a power plant turns chemical energy into thermal energy, then motion, then electrical energy; a battery turns chemical energy into electrical energy; a hand warmer turns chemical energy into thermal energy; pumped storage turns electrical energy into gravitational potential energy and back. Energy is conserved, so the input equals the useful output plus the energy that spreads out as waste heat. Efficiency = useful energy out ÷ total energy in × 100 percent.
Why heat engines cannot reach 100 percent. A heat engine takes in thermal energy at a high temperature, does some work, and must release the rest to a cooler place. If the energy had nowhere cooler to go, the engine would stop. That is why every steam power plant needs cooling water or cooling towers, and why efficiency is limited even with perfect engineering. A hand warmer is different: its goal is the heat itself, so nearly all of the released chemical energy is useful.
Worked example: a coal plant. EIA reports heat rate, the Btu of fuel energy used per kWh of electricity. For U.S. coal plants in 2024 it was 10,777 Btu/kWh. One kWh of electricity contains 3,412 Btu, so efficiency = 3,412 ÷ 10,777 = 31.7 percent. For every kWh, 7,365 Btu, or 68.3 percent of the fuel energy, becomes waste heat. Since 1 Btu = 3.6 × 106 J ÷ 3,412 = 1,055 J, the fuel energy for one kWh is 10,777 × 1,055 J = 11.37 MJ. Missouri’s delivered coal averaged 8,884 Btu per pound in 2024, so each kWh needs 10,777 ÷ 8,884 = 1.213 lb of coal, about 550 g. A natural gas plant at 7,754 Btu/kWh has an efficiency of 44.0 percent, and nuclear at 10,443 Btu/kWh has 32.7 percent.
Energy density and the fuel table. Coal’s 8,884 Btu per pound is 20.7 kJ per gram, against 55.5 kJ/g for methane. Methane also releases less carbon dioxide per kWh at plant efficiencies: a gas plant at 44.0 percent burns 10.19 mol of methane per kWh (3,600 kJ ÷ 0.440 ÷ 802.56 kJ/mol), which makes about 449 g of CO2. EIA’s whole-state average for Missouri’s electricity in 2024 was 1,456 lb/MWh, about 660 g/kWh. The comparison uses a simple model, so state its limit: it ignores the mix of plants, methane leaks and other losses.
Designing for fewer losses. To improve a device you choose a criterion and a constraint. Capturing the waste heat from a plant, using insulation in a hand warmer, or choosing a battery over a heat engine each target different losses. Pumped storage loses energy at every conversion, which is the reason its net generation can be negative in a given year.
Your questions. Which part of the coal-to-electricity chain loses the most energy? What data would you need to compare two power plants fairly? Write one device you could build at home that converts one form of energy to another, and name the form that is wasted.
📖 Read for this lesson
The reading opens over the lesson; close it to come back to exactly where you were. The checks below draw on it.
Formative check
Work through these before moving on. They are not graded — they tell you whether the standard below has landed yet.
A natural gas plant with a heat rate of 7,754 Btu per kWh has an efficiency of percent (nearest 0.1).
EIA reports Missouri pumped storage with a net generation of −49,050 MWh in 2023. A negative value means that, over the year, the plants
Simulation & tools
Energy forms and changes
Open the Systems screen. Build a chain: a source (the faucet or the sun), a converter (generator or solar panel) and a user (bulb or heater). Run it and watch the energy symbols. (1) Record the forms of energy at each step. (2) Note where energy symbols leave the chain as heat. (3) Swap one part and compare what reaches the user. Then, using the heat-rate table in this lesson’s reading, label your diagram with the coal plant’s 31.7 percent efficiency. No device? Use the reading’s table instead: for the 2024 coal, gas and nuclear heat rates, calculate each efficiency and draw the three energy-flow diagrams on paper, showing useful electricity and waste heat per kWh.
Open in a new tab ↗ · PhET Interactive Simulations, University of Colorado Boulder · CC BY 4.0
Using the heat rates and Missouri coal data in this lesson’s reading, calculate for a coal plant (a) the efficiency, (b) the waste heat per kWh in Btu, and (c) the pounds of coal per kWh at Missouri’s 8,884 Btu/lb. Then draw or describe the energy-flow chain from coal to household light and name one change that would waste less energy and one constraint on making it, such as cost or the temperature of the cooling water.
How confident are you that you can calculate efficiency from a heat rate and explain where energy goes in a conversion device?
Practice
Work these on paper or in your notebook, then open Check your answer. Aim for all of Fluency and Application; try at least one Challenge.
Printable version: this unit’s practice workbook (PDF)
Fluency
Build speed and accuracy with the core skill.
- A U.S. coal plant has a 2024 average heat rate of 10,777 Btu/kWh. Calculate its efficiency (one kWh = 3,412 Btu).
Check your answer
Answer: 31.7 percent3,412 ÷ 10,777 = 0.3166. - Find the efficiency of a nuclear plant with a heat rate of 10,443 Btu/kWh and a petroleum plant at 11,200 Btu/kWh.
Check your answer
Answer: Nuclear 32.7 percent; petroleum 30.5 percent3,412 ÷ 10,443 = 32.7%; 3,412 ÷ 11,200 = 30.5%. - What percent of the fuel energy becomes waste heat in the coal plant above?
Check your answer
Answer: 68.3 percent100 − 31.7 = 68.3. - Name the main energy conversions in a coal plant, in order.
Check your answer
Answer: Chemical energy of the coal → thermal energy (steam) → motion of the turbine → electrical energy; waste heat leaves at each step.
Application
Use the skill in context. Show your reasoning.
- Estimate the coal burned for Labadie’s 14,401,714 MWh in 2024, using a heat rate of 10,777 Btu/kWh and Missouri coal at 8,884 Btu/lb. Give the answer in million short tons (2,000 lb).
Check your answer
Answer: about 8.7 million short tons (an estimate)Heat input: 14,401,714,000 kWh × 10,777 = 1.5521e+14 Btu. ÷ 8,884 = 1.7470e+10 lb. ÷ 2,000 = 8.7352e+06 tons. - Callaway (nuclear) generated 10,525,784 MWh in 2024. Using a heat rate of 10,443 Btu/kWh, how many Btu of waste heat did it release? (kWh = 3,412 Btu)
Check your answer
Answer: about 7.40e+13 BtuWaste per kWh = 10,443 − 3,412 = 7,031 Btu; × 10,525,784,000 kWh = 7.401e+13 Btu. - Suppose (illustrative) that 6.0 percent of the electricity from the coal plant is lost in the wires before it reaches a house. What fraction of the coal’s energy reaches the house?
Check your answer
Answer: 29.8 percent31.7% × 0.940 = 29.8%. - A pumped-storage plant (illustrative numbers) uses 100.0 MWh to pump water uphill and then generates 78.0 MWh when the water is released. Find its round-trip efficiency and net generation.
Check your answer
Answer: 78 percent; net generation −22.0 MWh78.0 ÷ 100.0 = 78.0%; net = 78.0 − 100.0 = −22.0 MWh. EIA reported a negative net generation for Missouri pumped storage in 2023.
Challenge
Stretch problems. Expect to think before you write.
- A natural gas plant (efficiency 44.0 percent) burns methane, releasing 802.56 kJ per mole with gaseous water. Calculate the grams of CO2 produced per kWh of electricity (3,600 kJ) and compare it with Missouri’s 2024 average of 1,456 lb/MWh (about 660 g/kWh).
Check your answer
Answer: About 449 g/kWh, roughly 68 percent of the state averageFuel energy = 3,600 ÷ 0.440 = 8,181 kJ; moles CH4 = 10.19; × 44.0095 g/mol = 449 g. The state average includes all plants. - How many kilograms of Missouri coal (20.7 kJ/g) deliver the same energy as 1.00 kg of methane (55.5 kJ/g)? Why does that matter for a power plant’s fuel handling?
Check your answer
Answer: 2.69 kg of coal; coal has lower energy density, so far more mass must be delivered, stored and moved per unit of energy55.51 × 1,000 g = 55,513 kJ; ÷ 20.67 kJ/g = 2,686 g.
Review
Keep earlier skills sharp.
- Burning 1.00 mol of propane releases 2,219.15 kJ (liquid water). How much energy does 250.0 g release? (molar mass 44.0956 g/mol)
Check your answer
Answer: 12,581 kJ250.0 ÷ 44.0956 = 5.669 mol; × 2,219.15 = 12,581 kJ. - A 100.0 g sample of water absorbs 3,350 J. By how many degrees does it warm?
Check your answer
Answer: 8.0 °C3,350 ÷ (100.0 × 4.184) = 8.01. - How many moles of CO2 are produced when 3.00 mol of methane burns completely?
Check your answer
Answer: 3.00 mol (1 : 1 ratio)CH4 + 2O2 → CO2 + 2H2O gives one CO2 per CH4.
Power Plant Heat Rates, Missouri Coal and Pumped Storage
EIA Electric Power Annual Table 8.1, EIA FAQ on power plant efficiency, EIA Missouri State Electricity Profile 2024 (Tables 5, 6, 7), and Ameren Missouri’s hydroelectric web page, all retrieved 2026-11-15. Efficiencies and the Labadie coal estimate are SLS calculations. · Public domain (EIA data), with SLS commentary and calculations; one short fact from Ameren Missouri’s public web page, cited by link
Why this reading. It gives the published heat rates that turn into efficiencies, Missouri’s coal and carbon dioxide numbers, and the pumped-storage figures, so you can do the unit’s power-plant and energy-conversion questions from real data. Numbers marked “estimate” combine published values in a way you can repeat.
Heat rate and efficiency
EIA defines heat rate as the energy a power plant uses to make one kilowatt-hour of electricity, expressed in British thermal units (Btu) per net kWh. To turn a heat rate into an efficiency, divide 3,412 Btu (the energy in one kWh) by the heat rate. EIA’s average operating heat rates for U.S. power plants (Table 8.1) are:
| Year | Coal | Natural gas | Nuclear | Petroleum |
|---|---|---|---|---|
| 2015 | 10,495 | 7,869 | 10,458 | 10,687 |
| 2020 | 10,655 | 7,725 | 10,446 | 11,259 |
| 2024 | 10,777 | 7,754 | 10,443 | 11,200 |
These are national averages, not Missouri plants. Recomputed 2024 efficiencies: coal 31.7%, natural gas 44.0%, nuclear 32.7%, petroleum 30.5%.
Missouri coal and carbon dioxide (EIA Missouri profile)
- Delivered coal heat value, 2024: 8,884 Btu per pound; sulfur content 0.28 percent.
- 2024 coal generation: 38,831,623 MWh of 66,875,710 MWh total. Labadie, the largest plant, generated 14,401,714 MWh; Callaway (nuclear), 10,525,784 MWh.
- Electric power industry carbon dioxide: 1,456 pounds per MWh and 44,270 thousand metric tons in 2024. Dividing the state totals gives 662 kg per MWh, close to 1,456 lb/MWh = 660 kg/MWh.
Estimate: coal burned for Labadie in 2024
Using the U.S. average coal heat rate (10,777 Btu/kWh) and Missouri’s average coal heat value (8,884 Btu/lb), each kWh takes about 1.213 lb of coal. For 14,401,714,000 kWh that is about 17.5 billion pounds, or 8.7 million short tons. This is an estimate: Labadie’s own heat rate and coal differ from the averages.
Pumped storage and Taum Sauk
Ameren Missouri’s public web page describes the Taum Sauk Energy Center as storing the energy of 1.5 billion gallons of water, “like a giant battery.” Water is pumped uphill when electricity is cheap and released through turbines when it is needed. EIA’s net generation for Missouri pumped storage was 147,440 MWh in 2024 and −49,050 MWh in 2023. A negative net generation means the plants used more electricity pumping water uphill than they generated coming back down. EIA does not explain why 2024 is positive, so compare more than one year before you draw a conclusion.
Energy density check
The coal figure is 20.7 kJ per gram of delivered coal. NIST-based values from the previous lesson give methane 55.5 kJ/g and octane 47.9 kJ/g, so a gram of Missouri coal carries well under half the energy of a gram of methane.
Sources: EIA FAQ: What is the efficiency of different types of power plants? (eia.gov); EIA Electric Power Annual, Table 8.1 average operating heat rate (eia.gov); EIA Missouri State Electricity Profile 2024 (eia.gov); EIA Missouri tables (xlsx) (eia.gov); Ameren Missouri hydroelectric energy centers (Taum Sauk) (ameren.com)