THE VR SCHOOL
  • Schools & Districts
    • License the academy
    • Free program for your students
    • Request a demo
  • Catalog
    • AI & Data
    • Cybersecurity & Web
    • Programming
    • Health Science
    • All Guilds
    • All courses
  • Families
  • Accreditation
  • Log In
  • Request a demo
  • Home
  • Courses

RLP Algebra 1B — Functions, Exponential and Quadratic Models

Curriculum

  • 5 Sections
  • 23 Lessons
  • 10 Weeks
Expand all sectionsCollapse all sections
  • Unit 1: Functions
    5
    • 1.1
      One Input, One Output: What Makes a Function
      50 mins
    • 1.2
      Reading Graphs and Tables: Features and Average Rate of Change
      50 mins
    • 1.3
      Pieces, Steps and Corners: Piecewise and Absolute Value Functions
      50 mins
    • 1.4
      Working Backward: Tiered Rates and Inverse Functions
      100 mins
    • 1.5
      Performance Task — Decode a Utility Bill
      150 mins
  • Unit 2: Introduction to Exponential Functions
    5
    • 2.1
      Adding or Multiplying? Linear and Exponential Change
      50 mins
    • 2.2
      Sequences and Exponent Rules, Including Rational Exponents
      50 mins
    • 2.3
      Reading the Rate: Interpreting and Rewriting Exponential Expressions
      50 mins
    • 2.4
      Building and Graphing Exponential Models
      100 mins
    • 2.5
      Performance Task — Exponential or Not?
      150 mins
  • Unit 3: Introduction to Quadratic Functions
    5
    • 3.1
      A New Pattern: Area, Second Differences and Quadratic Growth
      50 mins
    • 3.2
      Polynomial Arithmetic: Adding, Subtracting and Multiplying
      50 mins
    • 3.3
      Three Forms, One Parabola: Vertex Form and Transformations
      50 mins
    • 3.4
      Falling Objects and Revenue: Quadratic Models in Context
      100 mins
    • 3.5
      Performance Task — Launch Lab
      150 mins
  • Unit 4: Quadratic Equations
    5
    • 4.1
      Solving Quadratics by Square Roots and Factoring
      50 mins
    • 4.2
      Completing the Square
      50 mins
    • 4.3
      Deriving the Quadratic Formula, and What Its Solutions Can Be
      50 mins
    • 4.4
      Where Paths Cross: Linear-Quadratic Systems and Choosing a Method
      100 mins
    • 4.5
      Performance Task — Proof and Design Portfolio
      150 mins
  • Unit 5: Missouri Algebra I Supplement
    3
    • 5.1
      Units, Rates and Scale: Making Quantities Make Sense
      50 mins
    • 5.2
      Functions by Name: Notation, Graphs, Sequence Terms and Division by a Monomial
      50 mins
    • 5.3
      Two-Way Tables: Relative Frequencies and Associations
      50 mins

Performance Task — Decode a Utility Bill

Unit 1  ·  Culminating Performance Task  ·  Lesson 5 of 23

Performance Task — Decode a Utility Bill

A1.LQE.A.3RLP-ALG1B
Hands compare two blank utility bills with stepped graphs, a meter, and a household choosing a cheaper plan.
By the end of this lesson I can…

build, graph, invert and compare piecewise functions for a real utility rate schedule, and recommend a choice for a household in writing and orally.

Instruction

Utility bills are functions that most households never see written down. This task writes one down, and uses it.

1. Choose a rate schedule. All three routes earn full credit, and all three support every part of this task.

  • Route A — Schedule A, printed here (illustrative rates). A tiered residential electric plan: a fixed charge of $10.00 a month, then $0.40 per kWh for the first 300 kWh and $0.50 per kWh for everything above 300 kWh. Sample bills: 100 kWh → $50.00; 250 kWh → $110.00; 300 kWh → $130.00; 450 kWh → $205.00; 800 kWh → $380.00.
  • Route B — Schedule B, printed here as a table (illustrative rates). A three-tier plan from the same utility with no fixed charge. You are given the bills, not the formula, so you must recover the structure from the table — which is exactly what step 5 asks of the second plan.
    kWh used01002002503004006008001,0001,200
    Monthly bill$0$33.00$66.00$82.50$104.50$148.50$236.50$360.50$484.50$608.50
    Check your work: the two schedules cost the same at 962.5 kWh, where both bills are $461.25. Below that Schedule B is cheaper; above it, Schedule A is.
  • Route C — a published Missouri schedule. Every Missouri electric and water utility posts its residential rates: Ameren Missouri, Evergy, Liberty, City Utilities of Springfield and the municipal electric and water departments all publish current rate sheets (tariffs) on their own websites, and the Missouri Public Service Commission posts the approved tariffs of the utilities it regulates at psc.mo.gov. Use your household’s utility, or any Missouri utility you choose. Some Missouri schedules charge less, not more, per kWh above a block in winter; a decreasing tier is still a piecewise function. Record the source, the page or document name and the date. If the schedule is complex, with time-of-use periods, seasons or fixed charges, choose one season and one plan and say what you left out.

Routes A and B need no internet at all. If you take Route C, compare your schedule with Schedule B in step 5, so you still have two plans in two different representations.

2. Build the function. Define the input (kWh, or hundreds of cubic feet of water, per month) and the output (dollars). Write the bill as a piecewise function with each piece’s interval. Include any fixed monthly charge as a constant term, and explain in a sentence what each coefficient and constant means.

3. Graph and describe. Graph the function by hand and with Desmos, with labeled axes and scales. State a sensible domain and range for a typical household. Where do pieces meet, and is there a jump? Compute the average rate of change on each tier and on one interval that spans two tiers, and interpret each in dollars per unit.

4. Invert. Find the inverse of each piece. Use it to answer a real question: “With a $120 monthly budget for electricity, how much can we use?” Explain why your function has an inverse, or, if it has a flat stretch, why it does not everywhere.

5. Compare. Represent a second plan as a table or a graph rather than a formula, and compare it with your first. If you took Route A, the second plan is Schedule B’s table; if you took Route B, the second plan is Schedule A; if you took Route C, use Schedule B’s table. Find where the two plans cost the same, and describe which plan is cheaper for which usage.

6. Recommend. Choose one of three households: your own (optional); a family of four in Springfield in July, using about 1,100 kWh; or a two-person apartment in St. Louis in April, using about 280 kWh. Recommend a plan or a usage target, and say what the tiers reward and penalize. Consider fairness: who is helped and who is hurt by increasing tiers?

The presentation. Three to four minutes, live or recorded: show the graph, explain one tier boundary, answer the budget question with the inverse, and give your recommendation. Expect one question about how the bill would change if a rate rose.

What strong work does. It keeps units on every number, checks one hand calculation against a real or sample bill, and explains the mathematics to a reader who has never heard of a piecewise function.

📖 Read for this lesson

The reading opens over the lesson; close it to come back to exactly where you were. The checks below draw on it.

  • Benchmarks for a Utility Bill: Real State Averages and Three Household Usage RecordsEIA Electric Power Monthly Table 5.6.A (released Oct. 23, 2026) and EIA Electric Sales, Revenue, and Average Price Table 5A (2024 data, released Oct. 7, 2025); the three household usage records are constructed teaching data and are illustrative · about 3 min

    Real state price benchmarks and a full year of usage for three households, so your recommendation rests on a year rather than one month.

Formative check

Work through these before moving on. They are not graded — they tell you whether the standard below has landed yet.

+50 XP

A utility charges a fixed $10 a month plus $0.40 per kWh up to 300 kWh. Which expression gives the bill for k ≤ 300?

The fixed charge is a constant term; the per-kWh charge is the coefficient of k.
Fill in the blank

On the illustrative tiered rate, the average rate of change from 0 to 300 kWh is $ per kWh, and from 300 to 450 kWh it is $ per kWh.

Quick self-check

How confident are you that you can model a real rate schedule with a piecewise function, invert it and use it to advise a household?

Not yetVery confident

Unit 1 checkpoint

Do this before you start the task. It covers the whole unit and tells you what to review first.

+50 XP

For B(t) = 100 − 12.5t, what is B(4)?

100 − 50.
Myth or Fact?

A graph that a vertical line crosses twice is a function.

Two crossings mean two outputs for one input.
Fill in the blank

For the battery, a sensible domain is 0 ≤ t ≤ .

+50 XP

Average rate of change of the hike from hour 0 (3,000 ft) to hour 4 (6,000 ft)?

3,000 ÷ 4.
Fill in the blank

The parking garage charges $3 per started hour; P(2.5) = $.

+50 XP

Where is the vertex of y = |x − 2|?

The inside is zero at x = 2.
+50 XP

y = f(x) and y = g(x) meet at (−1, 4) and (3, 12). The solutions of f(x) = g(x) are…

The x-coordinates of intersections.
+50 XP

The inverse of F(m) = 3.5 + 2.75m is…

Undo in reverse order.
Fill in the blank

With the tiered rate, C(450) = $.

Fill in the blank

A $195 bill corresponds to kWh.

Myth or Fact?

The tiered plan and the flat $0.45 plan cost the same at 600 kWh.

Both are $270.
+50 XP

Which function has an inverse on all real numbers?

Only the linear function with nonzero slope is one-to-one.

Submit: Decode a Utility Bill (600-900 words with function, graph, inverse and comparison) and presentation

Task: Model a real utility rate schedule as a piecewise function, graph it, find average rates of change and the inverse, compare it with a second plan given as a table or graph, and recommend a plan or usage target for a household.

Submission workflow

  1. Stage 1 — Plan. Rate schedule with source and date, input and output definitions with units, and the pieces you will model.
  2. Stage 2 — Peer-reviewed draft. A partner checks your function against one sample bill and your inverse on one value; submit a revision note.
  3. Stage 3 — Revised final. Function, graph, rates of change, inverse, comparison and a 600-900 word recommendation with sources.
  4. Stage 4 — Presentation. Three to four minutes, live or recorded, answering a question about a rate change.

How it is scored

CriterionWhat proficient looks like
Building the function (A1.LQE.A.3)Piecewise function correctly represents the real schedule, with intervals, constants and coefficients interpreted.
Graph and domain (A2.BF.A.3, A1.IF.B.4)Accurate labeled graph; sensible domain and range in context; tier boundaries shown correctly.
Rates of change (A1.IF.B.5)Average rates computed and interpreted in dollars per unit on each tier and across tiers.
Inverse (A2.BF.A.2)Inverse found for each piece and used correctly to answer a budget question; one-to-one condition discussed.
Comparison (A1.IF.C.9)Second plan represented differently; break-even found and interpreted.
Recommendation and presentation (MP.3, MP.4)Clear, fair recommendation with numbers; presentation answers the rate-change question with reasoning.

Missouri Learning Standards — Mathematics addressed: A1.LQE.A.3, A1.IF.C.9, A1.IF.B.4, A1.IF.B.5, A1.IF.A.2, A1.NQ.B.3, MP.3, MP.4

Extends beyond Missouri Algebra I (enrichment): A2.BF.A.3, A2.BF.A.2

Instructional focus: Function modeling of a real rate structure

Reading

Benchmarks for a Utility Bill: Real State Averages and Three Household Usage Records

EIA Electric Power Monthly Table 5.6.A (released Oct. 23, 2026) and EIA Electric Sales, Revenue, and Average Price Table 5A (2024 data, released Oct. 7, 2025); the three household usage records are constructed teaching data and are illustrative · Public domain (U.S. Energy Information Administration) for the state averages; SLS original for the constructed household records

Why this reading. The task asks you to recommend a plan for a household and to judge what the tiers reward and penalize. Two things are needed for that and are not in the lesson: something real to measure your schedule against, and a year of usage rather than a single month. This reading supplies both. It does not replace Schedule A or Schedule B, which are printed in the lesson; it is what you hold them up against.

1. Real benchmarks

From EIA Electric Power Monthly, Table 5.6.A, released October 23, 2026, the average price of electricity to Missouri residential customers was 16.02 cents per kWh in August 2026 and 15.32 cents per kWh in August 2025 — a rise of (16.02 − 15.32) ÷ 15.32 = 0.0457, about 4.6% in twelve months. EIA also reports that in 2024 the average Missouri residential customer bought about 1,001 kWh a month and the average U.S. residential customer about 863 kWh a month (Table 5A of Electric Sales, Revenue, and Average Price).

Use these numbers as a sanity check on any schedule you model, your own included. An effective rate far from 16.02 cents, or a usage far from 1,001 kWh a month, is not necessarily wrong — Missouri households buy more electricity than the national average, and apartments less than houses — but it is something your report has to explain rather than ignore.

2. Schedule A and Schedule B, restated as effective rates

The two schedules in the lesson cross at 962.5 kWh, where both bills are $461.25. Confirm it from the definitions before you trust it. Schedule A is $10.00 fixed, then $0.40 for the first 300 kWh and $0.50 above: 10 + 0.40(300) + 0.50(662.5) = 10 + 120 + 331.25 = $461.25. Schedule B’s table implies $0.33 to 250 kWh, $0.44 from 250 to 600, and $0.62 above 600 (check any two rows: 148.50 + 0.44 × 200 = 236.50 at 600 kWh, and 236.50 + 0.62 × 200 = 360.50 at 800 kWh). So at 962.5 kWh: 0.33(250) + 0.44(350) + 0.62(362.5) = 82.50 + 154.00 + 224.75 = $461.25. The two agree, and the crossing is exact, not rounded.

UsageSchedule A billA, effective rateSchedule B billB, effective rate
280 kWh$122.0043.6 ¢/kWh$95.7034.2 ¢/kWh
600 kWh$280.0046.7 ¢/kWh$236.5039.4 ¢/kWh
962.5 kWh$461.2547.9 ¢/kWh$461.2547.9 ¢/kWh
1,100 kWh$530.0048.2 ¢/kWh$546.5049.7 ¢/kWh

Every effective rate in that table rises with usage, on both schedules. That is what an increasing tier structure is, and it is the fact your fairness paragraph has to reckon with.

3. Three household usage records (illustrative, written for this task)

Monthly electricity use in kWh. These are constructed to be plausible for their settings; they are not measured data and are not attributed to any utility.

MonthSpringfield, family of fourSt. Louis apartment, two peopleOzarks house with an electric car
January620310780
February560290740
March520275720
April500280700
May610270730
June880265820
July1,100275900
August1,150285910
September960290850
October640285760
November540295740
December640320790
Year total8,7203,4409,440
Monthly mean727287787

Why a year changes the recommendation

The Springfield household’s mean month is 727 kWh, comfortably below the 962.5 kWh crossing, so a recommendation based on the mean picks Schedule B. But July, August and September are all above the crossing, and those are the months where a bill hurts. Compute the year both ways, month by month, and compare the totals with the answer the mean gives you. An average of a nonlinear function is not the function of the average, and a tiered rate is nonlinear on purpose.

Then finish the fairness question with numbers. Which of the three households pays the highest effective rate on Schedule A, and which on Schedule B? Say who each schedule rewards, who it penalizes, and whether that matches what a tiered rate is usually said to be for.

Sources: EIA, Electric Power Monthly, Table 5.6.A (average retail price by state and sector, August 2026), released October 23, 2026 (eia.gov); EIA, Electric Sales, Revenue, and Average Price, Table 5A: 2024 Average Monthly Bill – Residential (released October 7, 2025) (eia.gov)

Up NextComplete & Continue →

Leave a Reply Cancel reply

Working Backward: Tiered Rates and Inverse Functions
Prev
Adding or Multiplying? Linear and Exponential Change
Next

© 2026 The VR School | Career content by Wiley | Powered by Sejal Learning Systems.

Join free · Accreditation · Privacy Policy · Terms of Service

Modal title

Main Content