
model a water blend with a rational function, solve for the blend that meets Missouri’s recommended standard, and recommend a blend with its costs and trade-offs.
Instruction
Some communities, in Missouri and elsewhere, draw groundwater that is too salty to drink on its own. Salt content is measured as total dissolved solids (TDS), in milligrams per liter. Missouri’s drinking water rules (10 CSR 60-4.070), matching the U.S. EPA’s secondary standards, set a recommended level of 500 mg/L. The U.S. Geological Survey counts water as fresh only below 1,000 mg/L; above that it is saline. One solution is to blend the groundwater with desalinated water, which is far lower in TDS but costs more to produce. Desalination by reverse osmosis is a proven technology, but the EPA notes that it is fairly expensive.
An illustrative model. The numbers here are invented for teaching; your task uses parameters you choose and justify. A town pumps 50 units (say, thousands of cubic meters) of groundwater a day at 1,200 mg/L and blends in x units of desalinated water at 300 mg/L. The total salt is 1,200(50) + 300x and the total volume is 50 + x, so the blend’s concentration is
C(x) = (60,000 + 300x) / (50 + x).
Check the ends: C(0) = 1,200, the groundwater alone. As x grows, C approaches 300, the horizontal asymptote, because the blend becomes almost all desalinated water. Some values: C(50) = 750, C(100) = 600, C(400) = 400.
Meeting the standard. Solve C(x) = 500: 60,000 + 300x = 500(50 + x), so 35,000 = 200x and x = 175 units. Because C is decreasing, any x ≥ 175 meets the recommended level. Rearranged for any target c between 300 and 1,200 (A1.CED.A.4):
x(c) = 50(1,200 − c) / (c − 300),
which gives 175 at c = 500 and grows without bound as c approaches 300: you cannot blend below the cleaner source.
Adding cost. If each unit of groundwater costs g dollars and each unit of desalinated water costs d, the daily cost is 50g + d · x(c), and the cost per unit of delivered water is that total divided by 50 + x(c), a combination of functions (A2.BF.A.1). Your recommendation must weigh the extra cost of each step toward cleaner water.
Choose your own groundwater TDS (a real well report from your region is ideal; otherwise label the figure illustrative), a desalinated TDS, and cost figures with sources or clear labels.
📖 Read for this lesson
The reading opens over the lesson; close it to come back to exactly where you were. The checks below draw on it.
Formative check
Work through these before moving on. They are not graded — they tell you whether the standard below has landed yet.
In the illustrative model, how many units of desalinated water bring the blend to the 1,000 mg/L fresh-water line?
With enough desalinated water, the illustrative blend could reach 250 mg/L.
Stage 1: define your variables with units, list your parameter values with sources or an ‘illustrative’ label, and write your concentration function. Sketch its graph by hand and mark where you expect the 500 mg/L solution to be.
How confident are you that you can build and solve a rational model for a real decision and defend a recommendation?
Unit 3 checkpoint
Do this before you start the task. It covers the whole unit and tells you what to review first.
Asymptotes of f(x) = (2x + 1)/(x − 4)?
(x2 − 25)/(x − 5) has a vertical asymptote at x = 5.
(x2 + 3x + 5)/(x + 1) = x + 2 + /(x + 1).
1/x + 1/(x + 2) = ?
(x2 + 4)/(x2 + 8) simplifies to 1/2.
Solution set of x/(x − 3) = 3/(x − 3)?
x/(x − 1) − 2/(x + 1) = 2/(x2 − 1) has the single solution x = .
Why can clearing denominators create an extraneous solution?
The x-coordinates where y = 3/x + 1/(x + 2) and y = 1 intersect are the solutions of 3/x + 1/(x + 2) = 1.
Solving 1/R = 1/R1 + 1/R2 with R1 = 6 and R2 = 3 gives R = ohms.
In a blend C(x) = (60,000 + 300x)/(50 + x), the horizontal asymptote y = 300 means…
A negative time that satisfies a work-rate equation is an extraneous solution.
Submit: Blending Water Supplies report (4-6 pages) + presentation to a mock water board
Task: Model the TDS of a blend of groundwater and desalinated water as a rational function of the volume of desalinated water. Graph it with labeled axes, interpret the asymptote, domain and intercept in context, solve for the blend that meets 500 mg/L and 1,000 mg/L, and rearrange the model to give volume as a function of target concentration. Build a cost-per-unit function and recommend a target, explaining the trade-off. Label every figure as sourced or illustrative.
Submission workflow
- Stage 1 — Plan. Variables with units, parameter values with sources or labels, the concentration function and a hand sketch.
- Stage 2 — Peer-reviewed draft. A partner re-solves one equation and checks for extraneous or out-of-context solutions; submit a revision note.
- Stage 3 — Final report. 4-6 pages: model, graph, solutions for both standards, the rearranged formula, the cost function, a recommendation and limitations.
- Stage 4 — Water-board presentation. Five minutes plus questions from classmates acting as board members. A recorded presentation is an equal-credit alternative.
How it is scored
| Criterion | What proficient looks like |
|---|---|
| Creating equations (A2.REI.A.1) | The concentration model and target equations are built correctly from the situation. |
| Solving (A2.REI.A.2 / A2.NQ.A.4) | Rational equations are solved correctly and every solution is checked in the original and in context. |
| Rearranging (A1.CED.A.4) | Volume is expressed as a function of target concentration and its behavior is explained. |
| Combining functions (A2.BF.A.1) | The cost per unit is built correctly from the component functions. |
| Interpretation (A2.IF.A.1) | Asymptote, intercept and domain are interpreted in context; constraints are stated (A2.REI.B.3). |
| Recommendation (MP.4) | The recommendation follows from the model, states assumptions and weighs the trade-off. |
The Salt Standard, and Three Towns That Have to Meet It
Missouri Code of State Regulations 10 CSR 60-4.070, Secondary Contaminant Levels; U.S. EPA, Secondary Drinking Water Standards; USGS Water Science School, Saline Water and Salinity; retrieved November 5, 2026; the three towns are SLS illustrative scenarios · Public domain (Missouri regulation; U.S. federal government text), with SLS original illustrative data as labeled
Why this reading. The performance task asks you to recommend a blend to a water board and defend it. A recommendation needs a legal target you did not invent, parameters you can name, and a cost you can compute. The standard below is real and is quoted from the regulation. The three towns are illustrative scenarios constructed for this lesson and describe no actual community; they exist so that every number in your model has a stated origin before you swap in figures of your own.
Table 1. The standard, and the line between fresh and salty
Missouri’s drinking water rules, 10 CSR 60-4.070, list “recommended secondary maximum contaminant levels” for community water systems; they match the U.S. EPA’s national secondary standards. Secondary standards are set for taste, odor, appearance and plumbing, not health, and they are recommendations rather than enforceable limits. The U.S. Geological Survey separately classifies water by its dissolved salt: fresh water has less than 1,000 parts per million, which for drinking water is the same as 1,000 mg/L.
| Constituent | Missouri / EPA secondary level | Where it comes from |
|---|---|---|
| Total dissolved solids (TDS) | 500 mg/L | 10 CSR 60-4.070(1); EPA secondary standard |
| Chloride | 250 mg/L | 10 CSR 60-4.070(1); EPA secondary standard |
| Sulfate | 250 mg/L | 10 CSR 60-4.070(1); EPA secondary standard |
| USGS class | Dissolved solids |
|---|---|
| Fresh | less than 1,000 ppm |
| Slightly saline | 1,000 to 3,000 ppm |
| Moderately saline | 3,000 to 10,000 ppm |
| Highly saline | 10,000 to 35,000 ppm |
Two targets, then, and your recommendation has to say which one you are aiming at: the 500 mg/L recommended level, or the 1,000 mg/L line that makes the water count as fresh at all. That is not a mathematical decision, and the report should not pretend it is.
The model
Blend Q units a day of groundwater at cg mg/L with x units of desalinated water at cd mg/L. Salt is conserved and volume adds, so
C(x) = (cgQ + cdx) / (Q + x), and solving for x gives x(c) = Q(cg − c)/(c − cd).
Table 2. Town A (illustrative): Q = 50, cg = 1,200 mg/L, cd = 300 mg/L
| Desalinated water x | 0 | 25 | 50 | 100 | 175 | 250 | 400 | 700 | 1,000 |
|---|---|---|---|---|---|---|---|---|---|
| Blend TDS, C(x) mg/L | 1,200 | 900 | 750 | 600 | 500 | 450 | 400 | 360 | 342.9 |
Check the two ends against the formula. C(0) = 60,000/50 = 1,200, the groundwater alone. For very large x the 60,000 and the 50 stop mattering and C(x) → 300, the horizontal asymptote, which is the desalinated water alone. In between, C falls steadily and never crosses 300. A blend cannot be cleaner than its cleanest ingredient, and that sentence is what the asymptote says in English.
Table 3. What each target costs (illustrative costs)
The prices here are constructed for this lesson. Suppose groundwater costs $0.55 a unit to pump and treat and desalinated water costs $2.10 a unit to produce. Daily cost is 0.55(50) + 2.10x(c), and the cost per unit of water actually delivered divides that by 50 + x(c).
| Target c (mg/L) | x(c) units | Water delivered | Daily cost | Cost per unit delivered |
|---|---|---|---|---|
| 1,200 (no blending) | 0 | 50.0 | $27.50 | $0.5500 |
| 1,000 (fresh-water line) | 14.286 | 64.3 | $57.50 | $0.8944 |
| 800 | 40.000 | 90.0 | $111.50 | $1.2389 |
| 600 | 100.000 | 150.0 | $237.50 | $1.5833 |
| 500 (secondary standard) | 175.000 | 225.0 | $395.00 | $1.7556 |
| 450 | 250.000 | 300.0 | $552.50 | $1.8417 |
| 400 | 400.000 | 450.0 | $867.50 | $1.9278 |
| 350 | 850.000 | 900.0 | $1,812.50 | $2.0139 |
The shape of that last column is the whole argument. Going from no treatment to the 1,000 mg/L fresh-water line costs 34 cents a unit. Going from 1,000 down to the 500 mg/L secondary standard costs another 86 cents — two and a half times as much for half as much improvement. Going from 500 to 350 costs another 26 cents and requires almost five times as much desalinated water. Every step toward the asymptote costs more and buys less, because x(c) has a vertical asymptote at c = 300 and runs away as you approach it. A recommendation that ignores the shape of this curve is a wish, not a plan.
Table 4. Two more towns (illustrative), so the answer is not one answer
| Town A | Town B | Town C | |
|---|---|---|---|
| Groundwater flow Q | 50 | 30 | 80 |
| Groundwater TDS cg | 1,200 | 950 | 1,650 |
| Desalinated TDS cd | 300 | 250 | 200 |
| x needed for 1,000 mg/L | 14.29 | already met | 65.00 |
| x needed for 500 mg/L | 175.00 | 54.00 | 306.67 |
| Lowest TDS reachable | 300 | 250 | 200 |
Town B is already fresh water with no treatment at all, and its rearranged formula returns x(1,000) = 30(950 − 1,000)/(1,000 − 250) = −2, a negative volume. That is not an extraneous solution — it satisfies the equation perfectly — it is a solution outside the constraint x ≥ 0, and the correct report of it is “no blending is required,” not “−2 units.” Town C needs nearly twice Town A’s treated volume to reach the same target, because its groundwater starts 450 mg/L saltier; its lower cd only helps once the target gets close to 300.
What to do about parameters
The standard in Table 1 is real and you should cite it. The town parameters are not, and if you use them you must say so in the same sentence that you use them — “illustrative values, not measured” — every time. If you want real figures instead, your local water supplier publishes an annual Consumer Confidence Report that lists measured TDS for each source, and the Missouri Department of Natural Resources’ Drinking Water Watch lists the same sampling results by system. Using a real number requires naming the system, the sampling date and the units; a number without those three things is an illustrative number whether or not it came from somewhere.
Sources: Missouri Code of State Regulations, 10 CSR 60-4 (Contaminant Levels and Monitoring), section 4.070 (sos.mo.gov); U.S. EPA, Secondary Drinking Water Standards: Guidance for Nuisance Chemicals (epa.gov); USGS Water Science School, Saline Water and Salinity (usgs.gov)
Four Reciprocal Formulas and the Tables They Produce
SLS original case file for Algebra 2 A Lesson 3.4; the resistor values are standard E24 catalog values and the lens is a 50 mm prime, but every tabulated situation is constructed for teaching · SLS original
Why this reading. The workshop asks you to rearrange a formula and then reason with the rearranged version. That second half is the part a worked example rarely shows, because reasoning with a formula means feeding it a range of inputs and noticing what it does. Here are four reciprocal formulas with their tables. The situations are constructed for this lesson; the arithmetic is exact.
1. The thin lens: 1/f = 1/do + 1/di, rearranged to di = fdo/(do − f)
A 50 mm lens. All distances in millimeters; the third column is the magnification di/do.
| Object distance do | 100 | 150 | 200 | 300 | 500 | 1,000 | 2,000 | 5,000 | 50,000 |
|---|---|---|---|---|---|---|---|---|---|
| Image distance di | 100 | 75 | 66.67 | 60 | 55.56 | 52.63 | 51.28 | 50.51 | 50.05 |
| Magnification | 1.000 | 0.500 | 0.333 | 0.200 | 0.111 | 0.053 | 0.026 | 0.010 | 0.001 |
Read the row backwards. As the object moves away the sensor barely moves: from 1 meter to 50 meters the image distance changes by 2.6 mm. The horizontal asymptote is di = 50, the focal length itself, which is why “focused at infinity” is a real setting on a lens and why a landscape and a distant building need no refocusing between them. Now read it forwards: as do falls toward 50 the denominator do − f falls toward zero and di runs away. At do = 55 mm the sensor would need to be 550 mm behind the lens, and at do = 50 there is no solution at all. The vertical asymptote at do = f is the physical fact that a lens cannot focus on something at its own focal length.
2. Resistors in parallel: 1/R = 1/R1 + 1/R2, rearranged to R = R1R2/(R1 + R2)
| R1 (Ω) | 6 | 100 | 150 | 220 | 1,000 | 4,700 |
|---|---|---|---|---|---|---|
| R2 (Ω) | 3 | 100 | 470 | 330 | 4,700 | 10,000 |
| R (Ω) | 2.00 | 50.00 | 113.71 | 132.00 | 824.56 | 3,197.28 |
| R as a share of the smaller one | 0.667 | 0.500 | 0.758 | 0.600 | 0.825 | 0.680 |
The combination is always smaller than either resistor and never smaller than half of the smaller one, and the last row shows where in that window it lands: equal resistors give exactly half, and the more unequal the pair, the closer the result creeps to the smaller resistor alone. The algebra says why: R = R1/(1 + R1/R2), and as R2 grows the fraction R1/R2 shrinks toward zero. Identical structure, identical behavior, different subject: this is exactly the lens formula with different letters.
3. Work rates: 1/A + 1/B = 1/T
| Situation | Equation | Solution | Reasonableness check |
|---|---|---|---|
| One pipe fills a tank in 6 h, a second in 3 h; together? | 1/6 + 1/3 = 1/T | T = 2 h | 2 < 3, the faster pipe alone |
| Crew A takes 6 h; together they take 4 h. How long for B? | 1/6 + 1/B = 1/4 | B = 12 h | B is the slow one, as it must be |
| A takes 5 h; together 3 h. B? | 1/5 + 1/B = 1/3 | B = 7.5 h | 3 < 5 |
| A takes 12 h; together 8 h. B? | 1/12 + 1/B = 1/8 | B = 24 h | 8 < 12 |
| B takes 4 h longer than A; together 3 h. A? | 1/t + 1/(t + 4) = 1/3 | t2 − 2t − 12 = 0, t = 1 ± √13 | 4.606 h and 8.606 h; 3 < 4.606 |
| A takes 6 h; together 7 h. B? | 1/6 + 1/B = 1/7 | B = −42 h | impossible |
The last row is the one to think about. The algebra is faultless and the answer is a negative time, because the premise is absurd: two crews working together cannot take longer than one of them alone. The equation does not know that, and it answers anyway. Compare it with the fifth row, where t = 1 − √13 ≈ −2.606 is also negative and also rejected. Both rejections are for the same reason — a context constraint, time > 0 — and neither is an extraneous solution, because both values genuinely satisfy the equation they came from. Extraneous means “fails in the original equation.” These fail in the original situation, which is a different failure and belongs in a different sentence of your report.
4. Dilution: c(x) = 1.2/(12 + x)
A 12-liter tank holding a 10% salt solution contains 12 × 0.10 = 1.2 liters of salt. Adding x liters of fresh water adds volume and no salt, so the concentration is 1.2/(12 + x).
| Fresh water added x (L) | 0 | 3 | 6 | 12 | 18 | 24 | 30 | 48 | 108 | 228 |
|---|---|---|---|---|---|---|---|---|---|---|
| Concentration (%) | 10.000 | 8.000 | 6.667 | 5.000 | 4.000 | 3.333 | 2.857 | 2.000 | 1.000 | 0.500 |
Rearranged for the volume needed to hit any target c (as a decimal): x(c) = 1.2/c − 12. It gives 18 at c = 0.04, matching the table, and 0 at c = 0.10, matching the starting point. The sensible domain is 0 < c ≤ 0.10: you cannot dilute up to a concentration higher than you started with, and no finite amount of water reaches zero. Watch the cost of the last few points: halving from 10% to 5% takes 12 liters, halving again to 2.5% takes 24 more, and reaching 0.5% takes 228 liters in total. The horizontal asymptote is c = 0, approached with effort that grows without bound — which is the practical reason engineers remove a contaminant rather than dilute it away.
The common structure. All four are the same algebraic object: something fixed divided by something that grows, plus a constant. Lens, resistor, work rate, dilution. When you meet the fifth one, rearrange it the same way and then build the table before you say anything about it.